jumonville.nick at gmail
Nov 18, 2010, 12:24 PM
Post #1 of 1
(352 views)
Permalink
|
|
Re: foundry-nsp Digest, Vol 94, Issue 10
|
|
It is most likely a software problem, try to upgrade the card, then reboot it. It might need the correct mbridge, I have seen this happen before. -Nick Jumonville On Thu, Nov 18, 2010 at 9:00 AM, <foundry-nsp-request [at] puck>wrote: > Send foundry-nsp mailing list submissions to > foundry-nsp [at] puck > > To subscribe or unsubscribe via the World Wide Web, visit > http://puck.nether.net/mailman/listinfo/foundry-nsp > or, via email, send a message with subject or body 'help' to > foundry-nsp-request [at] puck > > You can reach the person managing the list at > foundry-nsp-owner [at] puck > > When replying, please edit your Subject line so it is more specific > than "Re: Contents of foundry-nsp digest..." > > > Today's Topics: > > 1. Re: New MG8 switch blade BIMG8-10Gx4-v6-A > CARD_STATE_INTERACTIVE (Remco Bressers) > > > ---------------------------------------------------------------------- > > Message: 1 > Date: Thu, 18 Nov 2010 16:44:08 +0100 > From: Remco Bressers <remco [at] signet> > To: foundry-nsp [at] puck > Subject: Re: [f-nsp] New MG8 switch blade BIMG8-10Gx4-v6-A > CARD_STATE_INTERACTIVE > Message-ID: <4CE549C8.7060601 [at] signet> > Content-Type: text/plain; charset=ISO-8859-1 > > What happens if you login to the card itself (# rconsole 2) and reboot > the thing? You should see the boot log and reason why the card won't > work. Are the software versions OK? > > > -- > Regards, > Signet bv > > > Remco Bressers > > T 040 - 707 4 907 > F 040 - 707 4 909 > E rbressers [at] signet > > > > On 11/18/2010 03:49 PM, Dominic Douglas wrote: > > Hi Justin, > > > > I saw your problem with the XMR 10G blade, but the problem is harder > > then I expected. > > > > Lets go: > > > > 1. Removed blade from slot 2. > > 2. Sh mod: > > S2: Configured as BIMG8-10Gx4-v6 4-port 10GbE IPv4/v6 Module > > > > Log: > > Nov 18 14:20:17:N:Module was removed from slot 2 > > > > But the slot is already configured with the right module. I will remove > > the config and reconfigure it: > > > > 3. (config)#no mod 2 bimg8-v6-10g-4-port > > 4. (config)#module 2 bimg8-v6-10g-4-port > > 5. Sh mod: > > S2: Configured as BIMG8-10Gx4-v6 4-port 10GbE IPv4/v6 Module > > > > 6. Insert module: > > > > S2: Invalid Module CARD_STATE_DOWN (7) (previous state = > > CARD_STATE_SW_LOADED) > > > > End after the module startup: > > > > S2: BIMG8-10Gx4-v6-A 4-port 10GbE IPv4/v6 Module (OACL) > > CARD_STATE_INTERACTIVE 0 > > > > It might be a bigger problem. This (new) module is an A module: > > > > BIMG8-10Gx4-v6-A > > > > Our other modules: > > > > M1 (upper): BIMG8-MR Management Module Active > > M2 (lower): > > F1: BIMG8-SFM Switch Fabric Module Active > > S1: > > S2: BIMG8-10Gx4-v6-A 4-port 10GbE IPv4/v6 Module (OACL) > > CARD_STATE_INTERACTIVE 0 > > S3: > > S4: > > S5: > > S6: > > S7: BIMG8-1Gx40-SFP-v6 40-port 1 GbE IPv4/v6 Module (IPv6+OACL) > > CARD_STATE_UP 40 > > > > > > Extra logging: > > > > Nov 18 14:26:07:N:Module 2 is reset by mgmt (reason: boot to interactive > > mode) > > Nov 18 14:25:38:N:Module was inserted to slot 2 > > Nov 18 14:20:17:N:Module was removed from slot 2 > > Nov 18 13:36:35:N:Module 2 is reset by mgmt (reason: boot to interactive > > mode) > > Nov 18 13:36:10:N:Module 2 is reset by mgmt (reason: CLI command) > > Nov 18 13:24:17:N:Module 2 is reset by mgmt (reason: boot to interactive > > mode) > > Nov 18 13:23:48:N:Module 2 is reset by mgmt (reason: lp sync during > booting) > > Nov 18 13:22:19:N:Module was inserted to slot 2 > > > > > > The module is forced to interactive mode by the management. It might be > > a software problem.. > > > > Kind regards, > > > > Dominic > > > > > > > > > > > > > > > > On Thu, Nov 18, 2010 at 3:17 PM, Justin Suyk - Signet BV > > <jsuyk [at] signet <mailto:jsuyk [at] signet>> wrote: > > > > Hi, > > > > We had to remove the blade before changing the config. > > So : > > > > 1. remove module > > 2. remove the blade config (no module ... bi-...) > > 3. config the blade > > 4. insert the blade > > 5. get a beer > > > > > > Regards, > > Signet bv > > > > > > Justin Suyk > > > > T 040 - 707 4 907 > > F 040 - 707 4 909 > > Kvk 17089930 > > > > > > > > On 11/18/2010 03:11 PM, Dominic Douglas wrote: > >> > >> *Hi All, > >> > >> We do have a problem with one of our MG8 switches. We've added a > >> new BIMG8-10Gx4-v6-A blade, but after configuration the blade will > >> not recover from CARD_STATE_INTERACTIVE. > >> > >> S2: BIMG8-10Gx4-v6-A 4-port 10GbE IPv4/v6 Module (OACL) > >> CARD_STATE_INTERACTIVE 0 000c.db27.4560 > >> > >> Steps taken: > >> > >> 1. Reset module. > >> 2. Set type to the slot port. > >> 3. Turn on/off module. > >> > >> Unfortunately we can't find any logs about the new blade, only the > >> current state: **CARD_STATE_INTERACTIVE. > >> > >> Kind regards, > >> > >> Dominic > >> ** > >> > >> * > >> > >> > >> _______________________________________________ > >> foundry-nsp mailing list > >> foundry-nsp [at] puck <mailto:foundry-nsp [at] puck> > >> http://puck.nether.net/mailman/listinfo/foundry-nsp > > > > > > > > > > _______________________________________________ > > foundry-nsp mailing list > > foundry-nsp [at] puck > > http://puck.nether.net/mailman/listinfo/foundry-nsp > > > ------------------------------ > > _______________________________________________ > foundry-nsp mailing list > foundry-nsp [at] puck > http://puck.nether.net/mailman/listinfo/foundry-nsp > > End of foundry-nsp Digest, Vol 94, Issue 10 > ******************************************* >
|