pkranz at unwiredltd
Dec 22, 2006, 5:23 PM
Post #1 of 2
(810 views)
Permalink
|
Upon inserting a G8Ti into a running 6808, one of our G8Xi cards immediately started logging the following messages: Dec 22 15:42:16 10.20.30.42 Dec 22 15:42:16 SYST: FDB Scan: entry 0/3 marked 'remapped' Dec 22 15:42:16 10.20.30.42 Dec 22 15:42:16 SYST: FDB Scan: (2) sw/hw dpath mismatch slot 1 bucket 1 entry 0 Dec 22 15:42:16 10.20.30.42 Dec 22 15:42:16 SYST: FDB Scan: entry 1/0 marked 'remapped' Dec 22 15:42:16 10.20.30.42 Dec 22 15:42:16 SYST: FDB Scan: (3) sw/hw dpath mismatch slot 1 bucket 2 entry 0 Dec 22 15:42:16 10.20.30.42 Dec 22 15:42:16 SYST: FDB Scan: entry 2/0 marked 'remapped' Dec 22 15:42:17 10.20.30.42 Dec 22 15:42:16 SYST: FDB Scan: (4) sw/hw dpath mismatch slot 1 bucket 42 entry 0 Dec 22 15:42:17 10.20.30.42 Dec 22 15:42:16 SYST: FDB Scan: entry 42/0 marked 'remapped' Dec 22 15:42:17 10.20.30.42 Dec 22 15:42:16 SYST: FDB Scan: (5) sw/hw dpath mismatch slot 1 bucket 42 entry 3 Dec 22 15:42:17 10.20.30.42 Dec 22 15:42:16 SYST: FDB Scan: entry 42/3 marked 'remapped' Dec 22 15:42:17 10.20.30.42 Dec 22 15:42:16 SYST: FDB Scan: (6) sw/hw dpath mismatch slot 1 bucket 43 entry 0 Dec 22 15:42:17 10.20.30.42 Dec 22 15:42:16 SYST: FDB Scan: entry 43/0 marked 'remapped' Dec 22 15:42:17 10.20.30.42 Dec 22 15:42:16 SYST: FDB Scan: (7) sw/hw dpath mismatch slot 1 bucket 81 entry 3 Dec 22 15:42:17 10.20.30.42 Dec 22 15:42:16 SYST: FDB Scan: entry 81/3 marked 'remapped' Dec 22 15:42:17 10.20.30.42 Dec 22 15:42:16 SYST: FDB Scan: (8) sw/hw dpath mismatch slot 1 bucket 82 entry 3 Dec 22 15:42:17 10.20.30.42 Dec 22 15:42:16 SYST: FDB Scan: entry 82/3 marked 'remapped' Dec 22 15:42:17 10.20.30.42 Dec 22 15:42:16 SYST: FDB Scan: max number of remaps (8) exceeded. slot 1 bucket 83 entry 0 Dec 22 15:42:17 10.20.30.42 Dec 22 15:42:16 SYST: Sys-health-check [ACTION] (hardware failure) (CARD_HWFAIL_FDB_OUT_OF_SYNC_ERROR) slot 1 Dec 22 15:42:17 10.20.30.42 Dec 22 15:42:16 SYST: Set card 1 to NON_OPERATIONAL due to Hardware failure Dec 22 15:42:17 10.20.30.42 Dec 22 15:42:17 SYST: Card in slot 1 is off line Now we can't get the card to come back, it says: 12/22/2006 17:21:21.11 <Erro:SYST> Card 1 already had Hardware Failure - set to Fail state 12/22/2006 17:21:18.16 <Info:SYST> Power up card 1 12/22/2006 17:21:18.11 <Info:SYST> Detected card[1] Any way to clear the remaps and rescan this card, I suspect a weird software glitch caused it to bounce like this to the point of failure, since the card has been running with out problems for years until we tried adding a G8Ti in another slot. Peter Kranz Founder/CEO - Unwired Ltd www.UnwiredLtd.com Desk: 510-868-1614 x100 Mobile: 510-207-0000 pkranz at unwiredltd.com
|