tmerrill at mathworks

Nov 13, 2008, 8:56 AM

Post #1 of 3 (1347 views)
Permalink
options cifs.max_mpx

Anybody consciously set this to something other than the default value
of 50?

If you have raised it, why did you do so, and more importantly, did you
see any negative impact on the *toaster*?

We're currently at 253 in one of our environments, and we're being
asked to bump it to the maximum recommended value (1124).

I've read the NOW articles on the parameter, so no need to explain what
it is or how it works. I'm just looking for experience, good or bad,
for raising it to the much larger values.

This environment already has our Windows machines beating the crap out
of a handful of 6070's, and I'm proceeding cautiously before giving
each Windows client EVEN MORE connections to the toasters...

Until next time...

The MathWorks, Inc. 508-647-7000 x7792
3 Apple Hill Drive, Natick, MA 01760-2098 508-647-7001 FAX
tmerrill [at] mathworks http://www.mathworks.com
---


jack1729 at gmail

Nov 13, 2008, 3:42 PM

Post #2 of 3 (1246 views)
Permalink
Re: options cifs.max_mpx [In reply to]

I think we are also at 253. We have a lot of citrix servers....each
with up to 200-250 citrix sessions on it at the same time. We did not
see anything on the downside after making the change....we did it based
on the output of cifs stats

HTH
Jack

Todd C. Merrill wrote:
> Anybody consciously set this to something other than the default value
> of 50?
>
> If you have raised it, why did you do so, and more importantly, did you
> see any negative impact on the *toaster*?
>
> We're currently at 253 in one of our environments, and we're being
> asked to bump it to the maximum recommended value (1124).
>
> I've read the NOW articles on the parameter, so no need to explain what
> it is or how it works. I'm just looking for experience, good or bad,
> for raising it to the much larger values.
>
> This environment already has our Windows machines beating the crap out
> of a handful of 6070's, and I'm proceeding cautiously before giving
> each Windows client EVEN MORE connections to the toasters...
>
> Until next time...
>
> The MathWorks, Inc. 508-647-7000 x7792
> 3 Apple Hill Drive, Natick, MA 01760-2098 508-647-7001 FAX
> tmerrill [at] mathworks http://www.mathworks.com
> ---
>
>
>


ggwalker at mindspring

Nov 13, 2008, 5:18 PM

Post #3 of 3 (1241 views)
Permalink
RE: options cifs.max_mpx [In reply to]

I believe the other option (NOW site has more detail) was 1153. So long
as the settings match on both sides (NetApp and Windows), you should be
in good shape with no negative effects.

There is a registry setting introduced in windows a few years back that
allows for a single TCP\CIFS session per user session, rather than a
TCP\single CIFS session shared by all users.

Glenn

-----Original Message-----
From: owner-toasters [at] mathworks [mailto:owner-toasters [at] mathworks]
On Behalf Of Jack Lyons
Sent: Thursday, November 13, 2008 6:42 PM
To: Todd C. Merrill
Cc: toasters [at] mathworks
Subject: Re: options cifs.max_mpx

I think we are also at 253. We have a lot of citrix servers....each
with up to 200-250 citrix sessions on it at the same time. We did not
see anything on the downside after making the change....we did it based
on the output of cifs stats

HTH
Jack

Todd C. Merrill wrote:
> Anybody consciously set this to something other than the default value
> of 50?
>
> If you have raised it, why did you do so, and more importantly, did
you
> see any negative impact on the *toaster*?
>
> We're currently at 253 in one of our environments, and we're being
> asked to bump it to the maximum recommended value (1124).
>
> I've read the NOW articles on the parameter, so no need to explain
what
> it is or how it works. I'm just looking for experience, good or bad,
> for raising it to the much larger values.
>
> This environment already has our Windows machines beating the crap out
> of a handful of 6070's, and I'm proceeding cautiously before giving
> each Windows client EVEN MORE connections to the toasters...
>
> Until next time...
>
> The MathWorks, Inc. 508-647-7000 x7792
> 3 Apple Hill Drive, Natick, MA 01760-2098 508-647-7001 FAX
> tmerrill [at] mathworks
http://www.mathworks.com
> ---
>
>
>

Netapp toasters RSS feed   Index | Next | Previous | View Threaded
 
 


Interested in having your list archived? Contact Gossamer Threads
 
  Web Applications & Managed Hosting Powered by Gossamer Threads Inc.