cpinkham at bc2va
Oct 11, 2007, 10:43 PM
Views: 345
Permalink
|
|
Channel scanner changing callsigns when set to "Minimal Updates"
|
|
Should the channel scanner to be updating callsigns in the channel table if the user runs with "Minimal Updates" set? I had to rescan the channels on my HDHomeRun tonight and after it was done, I noticed that all the callsigns that I had editted to match their counterparts from other sources were now reverted back to their original values. I had to go back in and change them all again manually in order to make sure that my channel records will work properly. I see 3 places in siscan.cpp that update the channel info. The first in SIScan::UpdatePMTinDB() only updates the callsign if the one in the DB is empty. That seems good. The second in SIScan::UpdateVCTinDB() always updates the callsign setting it to vct->ShortChannelName(i). It seems like this should be checking 'renameChannels' before doing this and should default to using the callsign from the DB as UpdatePMTinDB() does. The third in SIScan::UpdateSDTinDB() always sets the callsign field to the service name. This code also knows whether the channel exists in the table already, so it seems like it could preserve the callsign field as well by getting the value from the DB and using it instead of renaming if 'renameChannels' is not set. I don't know enough about the scanner, but I'm assuming the one messing up my channels is UpdateVCTinDB(), but it seems like both of the last two should be corrected. Is there any reason that the callsign should be updated during a rescan with "Minimal Updates" set? -- Chris _______________________________________________ mythtv-dev mailing list mythtv-dev[at]mythtv.org http://mythtv.org/cgi-bin/mailman/listinfo/mythtv-dev
|