alan at lxorguk
Sep 18, 2002, 10:49 AM
Post #2 of 2
(479 views)
Permalink
|
On Wed, 2002-09-18 at 18:31, Jo=E3o Alfredo wrote: > Hello all, >=20 > Can I build a redundant bridge setup using heartbeat?? 802.1 bridging is already fault tolerant. If you have multiple bridged routes between nodes the spanning tree protocol bridges talks eliminates the loop. A change in the network will be detected and reconfiguration occurs.
|