sommerfeld at sun
Nov 21, 2005, 8:33 AM
Post #1 of 3
(1647 views)
Permalink
|
|
ALOM (BREAK Requested - Access Denied) (Was: LISA 2005 attendees?)
|
|
On Mon, 2005-11-21 at 11:17, John Stoffel wrote: > I'm using the ALOM port at the hookin from my Avocent CPS16, which is > controlled by conserver. Just to be sure we're talking about the same thing: You've got a serial cable between the Avocent and the port marked SERIAL MGT on the back of the V210, and nothing plugged into the NET MGT port? Unfortunately, my V210's are a few hundred miles away from me at the moment and I have them all hooked up through the NET MGT port. (they arrived when we were short on terminal server ports, so using the ALOM as a one-port TS made a lot of sense at the time...) > I just get: > > [halt sent] > > BREAK Requested - Access Denied > > When I try to send a break. I need to do '#.' to get to the sc> > prompt where I can do a 'break -y' and the 'console' to get back to > the PROM level, etc. I have not seen that, but I've only really used the NET MGT connection. Different accounts on the ALOM can have different permissions and I belive sending a break can be denied to an ALOM account. Did you explicitly log in or are you just using the default login you get on the serial port? > sc> showsc > Advanced Lights Out Manager v1.5.1 That's actually newer than the bits I'm currently running (1.4). - Bill _______________________________________________ users mailing list users [at] conserver https://www.conserver.com/mailman/listinfo/users
|